Skip to main content

Mobile A/C Training

Refrigerant capacity and mobile A/C service: part 2

June 15, 2021

One of the most frequently asked questions on tech help-line calls concerns refrigerant capacity: How much refrigerant is in that mobile A/C system, and have you checked to be sure the refrigerant is pure?
Read Article >

Mobile A/C training when you want it!

June 14, 2021

If you’ve been too busy or the COVID-19 situation has made it difficult for you to attend mobile A/C training MACS has the solution.
Read Article >

Refrigerant capacity and mobile A/C service

June 8, 2021

One of the most frequently asked questions on tech help-line calls is: How much refrigerant is in that mobile A/C system, and have you checked to be sure the refrigerant is pure?
Read Article >

Temperature testing detective work: The search for a diagnosis

May 25, 2021

Last week we closed our blog post with a discussion about an orifice tube system which had an evaporator outlet temperature that was about 20° warmer than the inlet. We mentioned that this could be an indication of a restricted orifice tube or a refrigerant undercharge. In applying this to diagnostics, it is important not only to understand what this represents, but also why.
Read Article >

What is your temperature testing data telling you?

May 18, 2021

If air conditioning systems were transparent where we could see inside them, then diagnostics would be faster and easier. We could look at the systems and see things right away that affect system operation, like restrictions and liquid levels in evaporators and condensers.
Read Article >

Pass the temperature probe

May 4, 2021

The first step is to run the A/C system for a few minutes to let it stabilize. Then both probes should be connected side by side at both points that will be temperature tested in the system. For example, if you were testing the temperature drop across the condenser, this would need to be done on both the discharge line and the liquid line.
Read Article >

Contact counts in temperature testing

April 27, 2021

Proper contact is vital when connecting to A/C lines using the contact type temperature thermometers. To determine if I am getting good contact, I always like to place both connectors side by side on the same line and observe the temperature readings.
Read Article >

MACS Mobile A/C Update Webinar Now Available On Demand

April 22, 2021

Every year the Mobile Air Climate Systems Association creates a special mobile A/C update clinic to help working technicians keep up with the rapidly changing mobile A/C service and repair...
Read Article >

Tips for taking your mobile A/C system’s temperature

April 20, 2021

The contact type units do indeed have a high degree of accuracy, but precautions must be taken when using them (especially connecting to lines) to ensure the accuracy. Otherwise, it is possible to get readings that are easily 5° to 10° off and that can lead to an incorrect diagnosis.
Read Article >

Temperature testing accuracy

April 13, 2021

Temperature readings can be easily used to determine if an orifice tube system might be undercharged, and they can also be used to charge an orifice tube system. But if the readings are not accurate, all they are going to do is cause you problems.
Read Article >

Then things got complicated!

April 9, 2021

It was a 2013 Camaro. The complaint was poor cooling and the temp really would not change when you switched it from heat to cool. In diagnosing the job, the technician found the blend door was stuck to where it was blending heat. Until it was pulled out, the tech was not sure if it was a bad actuator or door.
Read Article >

Avoiding an oily situation

April 6, 2021

If you own a mobile A/C repair shop this is when you start to gear up for it, by replenishing your parts inventories and an important segment of those inventories is compressor oil.
Read Article >